Posted on

Issue 03 (2021)

Avoidance of Common Mistakes during Failure Analyses and Misinterpretation of Lab Results – Part 1: Sampling

Frank Udo Leidich

For a proper failure analysis or root cause analysis (RCA) a great deal of data and evidence-based information is needed. Within this context, various types of samples from different locations need to be taken for chemical and/or metallurgical examination. Therefore, proper and correct sampling, without alteration of the composition or contamination of the samples, is of utmost importance. Unfortunately, this is often not practiced correctly and so the risk of incorrect conclusions is high. This article is intended to help personnel obtain these samples in a proper manner and avoid common and repeated mistakes.

PPCHEM® 2021, 23(3), 108–119

For Members only

Update on Predicting RIHT Using the UNB-CNER CANDU-6 PHT System Model

Olga Y. Palazhchenko, William G. Cook, Alex L. Martin, and Jennifer Lennox

Reduced heat transfer in CANDU steam generators has safety consequences such as lower margins to fuel dryout due to higher reactor inlet header temperature (RIHT). To identify methods to maintain the RIHT within operational margins, it is necessary to model the effect of thermal degradation mechanisms on boiler heat transfer.

A comprehensive steam generator heat transfer and fouling add-on has been developed at the University of New Brunswick, Canada, and previously benchmarked using historic data from Point Lepreau Nuclear Generation Station. The one-dimensional, steady-state heat transfer code mechanistically predicts the effect of primary-side fouling, and semi-empirically models the effects of divider plate leakage and secondary-side fouling. This paper presents the most recent predictive modelling, where simulations of post-refurbishment operation (2012–2042) were conducted based on the benchmarked mechanisms. The predictive simulations inform the timeline for mitigating strategies such as a primary-side clean during the plant’s operating lifetime.

PPCHEM® 2021, 23(3), 122–131

For Members only

IAPWS Seventh Meeting of the European HRSG Forum (EHF2021)
Highlights and Press Release

Barry Dooley and Bob Anderson

The seventh annual IAPWS European HRSG Forum was held on the 18th and 20th May 2021 as a virtual event. It was chaired by Barry Dooley of Structural Integrity and Bob Anderson of Competitive Power Resources. EHF2021 attracted 90 participants from 17 countries and included 55 users.

EHF is supported by the International Association for the Properties of Water and Steam (IAPWS) and is held in association with the Australasian Boiler and HRSG Users Group
(ABHUG) and the US HRSG Forum (HF). The 2021 EHF had two sponsors: Trace Analysis and Swan Analytical Instruments. The conference was organized by PPCHEM AG.

PPCHEM® 2021, 23(3), 132–133

ATP Testing – A Real Time Monitoring of Microbiological Growth in the Cooling Water Systems of Power Plants

Kiran Diwakar, Rajendra K. Saini, Upain Kumar Arora, Janakiraman Pattabhiraman, and Gopi Kanta Nayak

In power plants, the warm environment of recirculating cooling systems is ideal for the growth of microorganisms. As microorganism communities grow in cooling systems, they can attach to tubes, pipe walls, and cooling tower fills, and form biofilms. Uncontrollable biological growth causes fouling, loss of heat exchange capacity, equipment failure, and energy wastage.

Due to the large volume of a cooling system with a flow rate of 60000–75000m3·h–1 (500 MW plus unit) and the diverse types of bacteria, spores, and algae, no one chemical can kill everything. There must be proper selection of a biocide, adequate contact time, and real time monitoring techniques to allow control of biological problems.

The best solution for any system is the fast and early detection of biological contamination, and the setting up of proactive actions and subsequent corrective treatments. For the measurement of microbiological counts, we can use culture tests like the heterotrophic plate count (HPC) method. However, these culture tests only measure culturable organisms while adenosine triphosphate (ATP) testing measures all microorganisms within a sample. There are two types of ATP – intracellular ATP contained within living biological cells and extracellular ATP located outside of biological cells, which has been released from dead or stressed organisms.

In one thermal power plant cooling water system of NTPC Ltd., India, this technique was demonstrated with successful results.

PPCHEM® 2021, 23(3), 134–142

For Members only
Posted on

Issue 02 (2021)

Ngati Tuwharetoa Geothermal Assets Ltd Reboiler Plant Water/Steam Chemistry Improvements to Resolve Ongoing Corrosion Issues and Prevent Future Tube Failures

David Addison, Nik Vandervegte, and Nellie J. Olsen

Since its commissioning in 2010, the Ngati Tuwharetoa Geothermal Assets Ltd Kawerau reboiler plant has suffered from major corrosion and plant failure issues. Corrosion-related failures which occurred due to water/steam chemistry issues and interactions with plant materials have led to premature complete replacement of the tube bundles.

In 2018 a major root cause analysis was undertaken into the failures that included a detailed chemical and metallurgical investigation and successfully identified the failure mechanisms. A number of simple chemical treatment changes, including hydrogen sulfide neutralisation, pH correction and the application of corrosion inhibiting film forming substances, were carried out to successfully mitigate ongoing corrosion of the plant and to significantly extend asset life.

PPCHEM® 2021, 23(2), 56–72

For Members only

A Novel Combination of CMIT/MIT with a New Non-biocide Dispersant in Cooling Tower Biofilm Control

Henk A. Jenner

Microbial biofilm communities are a significant problem in recirculating cooling water systems resulting in reduced heat transfer efficiency, and the risk of microbial influenced corrosion (MIC) and Legionella infection of operators. Most biocides are generally only effective in the control of microorganisms when in the water phase. A new dispersant was tested that is able to remove biofilms from their substrate, releasing the biofilm community into the water phase. This study investigated how the effectiveness of (chloro)methylisothiazolinone/methylisothiazolinone (CMIT/MIT) (non-oxidizing biocide) in a heavily fouled scale cooling tower model with condenser tubes could be improved by the new dispersant. Dosing tests with CMIT/MIT separately and combined with the new dispersant were performed with different CMIT/MIT concentrations. Microbial activity in both water samples and biofilm samples was measured by the analysis of adenosine triphosphate (ATP). Additionally, the biofilm mass in the transparent condenser tubes was visually inspected by photos. The new dispersant was shown to be effective in loosening the biofilm and the biocidal efficacy of CMIT/MIT was greatly increased due to this combination.

PPCHEM® 2021, 23(2), 74–81

For Members only

Online Analysis of Film Forming Amines

Harold Stansfield

Waltron has developed an online colorimeter for online analysis of film forming amines
(FFA). The design basis and development process are discussed. Data from beta testing and two working case studies are presented. The analyzer can monitor FFA-based products in a working range of 0–1 000 µg ⋅ L–1, with an accuracy of ± 2 % of full scale or ± 5 µg ⋅ L–1, with a lower detection limit of < 5 µg ⋅ L–1 as FFA.

PPCHEM® 2021, 23(2), 86–91

For Members only

IAPWS Fourth International Conference on Film Forming Substances (FFS2021) Highlights and Press Release

Barry Dooley

The IAPWS Fourth International Conference on Film Forming Substances (FFS2021) was held on the 23rd and 25th March 2021 as a virtual event chaired by Barry Dooley of Structural Integrity Associates. FFS2021 was a unique conference on a narrow topic in cycle chemistry control of power plants and steam generating facilities. In 2021 the conference attracted a record number of 130 participants from 28 countries which included 41 plant operators/users and 27 people from the Film Forming Substances chemical suppliers.

The FFS conferences are developed and supported by the International Association for the Properties of Water and Steam (IAPWS), and the FFS2021 was organized by PPCHEM AG, publisher of the PPCHEM® Journal. Three sponsors supported FFS2021: Trace Analysis, Fineamin Swiss Water-Treatment Chemicals and Swan Analytical Instruments.

PPCHEM® 2021, 23(2), 92–93

Posted on

Issue 01 (2021)

Technoeconomic Benefits of Film-Forming Amine Products Applied to Steam Surface Condensers

Sean H. Hoenig, Mahesh Budhathoki, Gregory Robinson, Claudia Pierce, Donald Meskers, Michael C. Ellis, and Richard W. Bonner III

In a conventional Rankine cycle, the majority of power plants employ surface condensers that use pumped cooling water to reject heat from the cycle. In such cases, heat rejection occurs in a shell and tube heat exchanger by filmwise condensation of low-pressure steam on stainless steel, titanium, brass, or copper-nickel tubing. To improve the thermal performance of steam surface condensers, a replenishable film-forming substance (FFS) can be applied to the condenser tubing to promote efficient dropwise condensation. Conventionally, film-forming amine product (FFAP) coatings protect boiler surfaces from oxidative corrosion, which substantially reduces the operation and maintenance costs. To quantify the technical and economic benefits of FFAP coatings applied to condenser tubing due to the promotion of dropwise condensation, a thermal resistance network model was established. Using a representative steam surface condenser, the improvements in thermal performance (overall heat transfer coefficient) and process parameters (net plant efficiency, cooling water flowrate, and turbine backpressure) were determined due to the enhancement in the condensation heat transfer coefficient. Experimentally measured condensation heat transfer coefficients for common condenser materials were compared with the modeling results and were found to be within attainable bounds. Finally, the trend in total heat exchanger cost reduction is generalized to understand the trade-off between reduced surface area for heat rejection and increase in coating application costs for a replenishable coating system.

PPCHEM® 2021, 23(1), 4–16

For Members only

The Role of Human Performance Science in Cycle Chemistry Improvement – Is This the Missing Link?

Brad Burns and Doug Hubbard

On most units assessed by the Electric Power Research Institute (EPRI) across the world, cycle chemistry is well controlled and good results are obtained a majority of the time. Fossil and combined cycle power plants on a global scale continue to boast higher cycle chemistry benchmarking scores, installation of new instrumentation and alarming, and management support for cycle chemistry. The exception, however, continues to be major cycle chemistry excursion events that happen infrequently, yet with great consequences.
Often, when an unmitigated major cycle chemistry upset event occurs, root cause investigations pin the event on inadequate skills or knowledge (of individuals). It is therefore believed that additional training and/or disciplinary corrective action solves the root cause of the event and will prevent poor operator response to out-of-spec chemistry from recurring.

But does this approach produce desired results? This article examines that question and offers an approach with the potential to lead your organization toward a more critical review of systems and processes where countermeasures and defenses are checked and tested to determine efficacy.
Incorporating the science of human and organizational performance into a cycle chemistry program may well be the “missing link” to obtaining true cycle water chemistry improvement by preventing chemistry-influenced damage that occurs when plant personnel don’t properly respond to acute and chronic cycle chemistry upsets.

PPCHEM® 2021, 23(1), 20–30

For Members only

Issues Related to the Measurement of the pH-Value in Pure and Ultrapure Water

Michael Rziha

In all my years working in the area of power plant chemistry, I have been repeatedly confronted with either specifications or operators requesting the measurement of the pH-value either in pure water or even in ultrapure water. This often results in useless, time consuming discussions when those “measurements” are made, where some “experts” simply compare those results versus “specifications” and request that this pH-value must be 7 ± 0.5, or something similar. When asked why this is specified for an ultrapure water (e.g. outlet mixed bed filter) with a conductivity of < 0.1 μS · cm–1, the most classic answer is we don’t know, but it is specified, hence it must be fulfilled. Consequently, those specifications and the hopeless and wrong trial to measure it will lead in many projects to costly delays and consumption of precious working hours of many people involved.
Every chemist with a sound chemical education and understanding will of course immediately understand that this measurement is not only useless (I would even say nonsense), but also unnecessary.
In this brief article, the background and scientific, chemical facts will be explained for why this measurement is dispensable.

PPCHEM® 2021, 23(1), 34–37

For Members only

2020’s Scientific and Technical Contributions

PPCHEM® 2021, 23(1), 40–45

Posted on

Issue 06 (2020)

Corrosion Product Monitoring – Key Parameters to Achieve High Accuracy and Reliable Analysis

Niken Wijaya 

Efforts have been made at AGL’s Liddell Power Station, Australia, to determine the best corrosion product monitoring practices in order to establish baseline data that are reliable and accurate. This effort is an outcome of the decision made to apply a film forming product (FFP) at Liddell Power Station, with the goal of minimising corrosion product transport from the boiler feed system to the boiler on all four units until its scheduled closure in 2022. Despite guidelines and studies done on this subject, there are still many knowledge gaps that need to be addressed. This paper aims to evaluate the accuracy of onsite ferrozine and porphyrin analyses for iron and copper analysis and how they compare to external analyses by inductively coupled plasma mass spectroscopy with an octupole reaction cell. This paper also investigates the influence of several key parameters on corrosion product monitoring including the use of an integrated corrosion product sampler, the use of smaller pore filter paper, the forms of corrosion products in the system, and the use of cation paper, which are critical in establishing the best practices for corrosion product monitoring. Liddell’s baseline data on corrosion product were used to evaluate the efficiency of the current cycle chemistry program and to verify the need for FFP dosing for corrosion protection.

PPCHEM® 2020, 22(6), 230–250

For Members only

The Challenges of Industrial Boiler Water Treatment

Brad Buecker and Tim Hughes

High-pressure steam generators for power production require high-purity makeup and feedwater and controlled boiler water chemistry to minimize corrosion and scale formation in the boilers, superheater/reheater circuits, and turbines. Numerous articles in the PPCHEM® journal over the last two decades have outlined these chemistries and their evolution.
However, while many heavy industries have high-pressure steam generators for cogeneration needs, these plants and many other smaller facilities also have low-pressure boilers that produce process steam. The lower heat fluxes and pressures in these steam generators somewhat alleviate the stringent treatment requirements necessary for highpressure units but offer more complexity in the choice of optimum treatment methods.
This article provides an overview of modern methods for protecting lower-pressure steam generators from factors that typically do not plague their high-pressure counterparts.

PPCHEM® 2020, 22(6), 252–259

For Members only

Heat Transfer Add-on to the UNB-CNER CANDU-6 PHT System Material Transport Model

Olga Y. Palazhchenko, William G. Cook, Alex L. Martin, and Dean C. Taylor

Reduced heat transfer in steam generators has safety consequences such as the risk of fuel dryout due to increasing reactor inlet header temperature (RIHT). To maintain the RIHT within the safe operating envelope, it is necessary to model factors that contribute to its rise, including chemical processes such as corrosion product transport and deposition and mechanical effects such as component degradation.
In the recent add-on to the UNB-CNER PHT Corrosion Product and Activity Transport Code, a combination of heat transfer mechanisms, updated thermodynamic equations for the properties D2O and H2O, station data, and the existing model capability of predicting primary-side material transport are used to create and optimize a one-dimensional simulation of a typical CANDU-6 boiler. Data from Point Lepreau Nuclear Generating Station is used to benchmark various model parameters, allowing for predictive simulations, where RIHT trends can be forecasted into the future using desired outage and boiler cleaning schedules.

PPCHEM® 2020, 22(6), 262–273

For Members only

Posted on

Issue 05 (2020)

Film Forming Corrosion Inhibitor with Improved Handling, Feeding, and Corrosion Control Properties for Steam Generators

Mahesh Budhathoki, Donald Meskers Jr., Claudia Pierce, and Gregory Robinson

Film forming amine (FFA) products containing octadecylamine (ODA) or oleyl propylenediamine (OLDA) are known to provide excellent corrosion protection to the alloys used in the steam-water cycle of power plants. However, product formulations based on these filming amines exhibit poor water solubility, which often hinders successful application due to formulation stability, feeding, and handling. In this work, the water solubility of an OLDA-based FFA product is significantly improved with the addition of a co-surfactant and its efficacy as a corrosion inhibitor in steam generators is evaluated. Research boiler experiments indicate that the vapor-liquid distribution ratio of OLDA decreases by enhancing its water solubility. Also, the conductivity after cation exchange (CACE) measured in steam suggests that under normal boiler operation conditions, unlike neutralizing amines or co-solvents, the added co-surfactant does not contribute to the CACE in steam. Furthermore, electrochemical and corrosion testing indicates that the water-soluble FFA product can effectively inhibit corrosion, which is attributed to its ability to form a hydrophobic film on metal surfaces, as suggested by the contact angle measurements.

PPCHEM® 2020, 22(5), 182–194

For Members only

Testing the Suitability of the AMI CACE Monitor for the Water-Steam Cycle at Lippendorf Power Plant

Karla Georgi-Kruggel

In the period from January 06, 2020, to June 30, 2020, an analyzer for the automatic and continuous determination of conductivity before and after a cation exchanger with electro-deionization was tested at the Lippendorf Power Plant of Lausitz Energie Kraftwerke AG, Germany.

This report describes the setup and outcome of the trial. In summary, the proof of suitability of the analyzer for the monitoring of the water-steam cycle and the control of the conditioning agent quantities was positively demonstrated for all tested measuring points.

PPCHEM® 2020, 22(5), 196–202

For Members only

Comparative Study on the Ion Exchange Removal of Gadolinium Nitrate under the Conditions of the Moderator System of a Nuclear Reactor Using Styrene- and Acrylic- Acid-Based Macroporous Weak Base Anion Resins

A. L. Rufus, Padma S. Kumar, C. S. Sanjana, and S. Velmurugan

The fission reaction in a nuclear reactor is regulated by adding “neutron poison” to the system. Gadolinium has a high neutron absorption cross section and hence is used for this purpose in the form of aqueous solution of gadolinium nitrate. After its intended use, the neutron poison is removed from the system using mixed-bed (MB) ion exchange resin columns. A comparative study between the styrene- and acrylic-acid-based macroporous weak base anion (MWBA) resins in the MB column was carried out. Based on the parameters evaluated, which include (i) extent of utilization of the ion exchange capacity, (ii) precipitation of gadolinium in the ion exchange column, (iii) pressure drop across the column and (iv) radiation stability, the use of acrylic-acid-based resin in the MB ion exchange column was found to be good. The ion exchange capacity for acrylic-acid-based MWBA resin was higher (2.6 mEq ∙ mL–1 of resin as against 2.0 mEq ∙ mL–1 for styrene-based MWBA resin), 65 % utilization capacity as against 50 % for styrene-based MWBA resin, less precipitation of gadolinium (0.001 % as against 0.004 %), a favorable pressure drop and better retention of ion exchange capacity on irradiation.

PPCHEM® 2020, 22(5), 204–213

For Members only

Posted on

Issue 04 (2020)

Sampling Points and Parameters for Low-Pressure Industrial Steam Generators

Brad Buecker and Ken Kuruc

Although thousands of low-pressure steam generators exist at industrial plants around the globe, the chemistry of such units has not received the same attention as that of high-pressure units. The conditions in these steam generators are typically not as harsh as in utility units, yet water/steam chemistry control is still very important for the plants’ steam/condensate systems. This article discusses many of the most important sampling points and parameters for industrial steam generators, and it illustrates the benefits of proper chemistry control to maintaining equipment reliability and availability.

PPCHEM® 2020, 22(4), 142–150

For Members only

Modelling of Mechanical Oxygen Removal in a Power Plant Deaerator

Daniel Zinemanas

Oxygen removal is an integral part of the water/steam cycle chemical treatment in power plants and is generally performed in the deaerator. Understanding of this process, particularly during transient conditions, is important to analyze the plant data, and for this goal modelling of this process can be helpful. It is thus the main motivation of this paper to develop a simple workable theoretical model of the mechanical oxygen removal process in a power plant deaerator. Results of the model are compared to power plant operational data and show a very good match between the calculated and the measured data. Thus, the model can be useful in understanding the deaerator’s behavior and performance as well as for design or training.

PPCHEM® 2020, 22(4), 152–157

For Members only

A Practical View on the Dissolution of Air in Demineralized Water

Robert Svoboda

The equilibrium of the components of air with water can be calculated by means of Henry’s law and the ionization equilibria. This article gives guidance for such calculations and covers conditions up to 100 °C. At 25 °C and 1013mbar atmospheric pressure, the equilibrium for oxygen in water is 8.4 mg · kg–1. With 410 ppm CO2 in air, its mass fraction in water is 694 μg · kg–1 CO2, where 595 μg · kg–1 are present as dissolved gas and 99 μg · kg–1 are ionized to HCO3-. The result is a slightly acidic water with pH = 5.65 and 0.89 μS · cm–1 conductivity. In generator cooling water systems with neutral water treatment, this will cause an increase in copper release. With alkaline water treatment, the contact with untreated air can lead to the deterioration of alkaline conditions.

PPCHEM® 2020, 22(4), 160–169

For Members only

Posted on

Issue 03 (2020)

Treating Make-up Water and Condensate by Reverse Osmosis in an LP Vinyl Records Pressing Plant

Pavel Hübner

At the Czech company GZ Media a.s., which produces vinyl records, the vinyl presses are heated by steam and after pressing, the steam is rinsed from the press by cooling water. The condensate therefore contains a high proportion of cooling water.

In the original system, the losses of steam and cooling water were replaced by filtrated and softened raw water. The polluted condensate was also treated by filtration and softening. The water used as make-up, which was originally considered drinking water, has been replaced for economic reasons by surface water with high salinity and alkalinity. Due to high operational costs and other considerations the original design was replaced with a new one in 2019.

The new system treats the mixture of raw water and cooled condensate by on-line coagulation followed by reverse osmosis. The hot condensate is cooled by heat exchange, which transfers the heat to the permeate as feedwater. The new system exhibits very low boiler blow-down, minimal consumption of chemicals and low operator attendance.

PPCHEM® 2020, 22(3), 104–109

For Members only

Calculations to Manage Phosphate and Caustic Treatment

Randy C. Turner

Phosphate and/or caustic (NaOH) treatment boiler water treatment is often employed to reduce the risk of corrosion.

This paper describes empirical calculations for proper control of phosphate and caustic treatment which could be incorporated into an Excel spreadsheet which includes several calculations, of which the most important are:

  1. Boiler water ammonia corrected pH
  2. Sodium to phosphate molar ratio
  3. Free sodium hydroxide concentration
  4. Amount of phosphate and/or caustic to dose for a specific concentration at the current operating pressure

This can also be used to calculate how much caustic must be added to an AVT treated boiler to achieve a desired pH-value.

PPCHEM® 2020, 22(3), 112–117

For Members only

The Impact of Low-Load Operation on Power Plant Chemistry

Frank Udo Leidich

Nowadays conventional power plants are more challenged in regard to load flexibility and especially frequent(very) low-load operation. While the so-called “dark doldrums” must be managed without de-stabilizing the grid,a bright sunny and windy day requires almost no conventional power generation. This kind of operation not onlystresses the plant components mechanically and thermally, leading to accelerated aging of the plant, but the physico-chemical operation also becomes more challenging. This paper highlights the most important aspects of theimpact of low-load operation on the chemical operation of a power plant. It is shown that it pays to operate the unitwith water and steam that is as clean as possible.

PPCHEM® 2020, 22(3), 118–129

For Members only

Posted on

Issue 02 (2020)

Corrosion Issues Caused by Changes in Pipe Cross-Sections

Andrés Rodríguez Pérez

Among the most detrimental corrosion phenomena observed in the power industry are those related to a sudden expansion of a fluid beyond the saturation point. The effects of such types of corrosion may be particularly aggressive due to a combination of physical factors and a variety of chemical mechanisms that could potentially be involved. Based on data collected from over one hundred inspections carried out in the power industry and refineries, this publication is aimed at building a stronger understanding of the issues to allow plant operators to predict areas of vulnerability, mitigate the risk of potential failures, and specify a correct chemical treatment program to operate their plant at its maximum level of performance and reliability.

PPCHEM® 2020, 22(2), 66–72

For Members only

Chloride Contamination of the Water/Steam Cycle in Power Plants: Part VII. Final Verdict on Vapor Ingress of Chlorinated Compounds via Weak Tube/Tubesheet Joints

Emmanuel K. Quagraine, Trever McNabb, Suzanne McNabb, Sheldon McNabb, Taneal Weiss, Gillian Bailey, Ashley Ponak, Brenna Janzen, and Janet Meyers

This paper concludes a series of publications on investigations at Shand Power Station (SaskPower) to understand selective chloride cycling in this plant. With naval brass tubesheet, dezincification was implicated as the corrosion mechanism at naval brass tube-to-tubesheet joints, which created vapor pathways for recirculating cooling water (RCW) chlorine compounds into the water/steam circuit, eventually forming chlorides. Replacing the tubesheet with Duplex 2507 SS, the expectation was that the chloride cycling would end. Yet it persisted. The paper provides evidence that even with new metallurgies, vapor ingress via weak tube-to-tubesheet joints has mainly been responsible for the persisting chloride cycling. Organochlorine compounds leaching from the tubesheet/shell interface gasket have also been shown to potentially contribute to the chloride cycling, to a major extent earlier on, but becoming less significant over time. Plugging of the leaking tubes at tube-to-tubesheet joints reduced the average daily increases in boiler chloride from 28.4µg⋅L–1 to 2.7µg⋅L–1, supporting the notion that the RCW was the principal source of the chloride contamination.

PPCHEM® 2020, 22(2), 74–90

For Members only

Posted on

Issue 01 (2020)

Dependence of the Corrosive Environment in BWRs on Operating Conditions

Yoichi Wada, Kazushige Ishida, Nobuyuki Ota, and Makoto Nagase

The effects of core management in a boiling water reactor (BWR) on radiolytic oxygen and hydrogen peroxide concentrations in the reactor water have been studied based on a radiolysis model. An increase in core flow promoted radiolysis of water in the core region since the amount of water present in the core region became larger and mass transfer from water to steam slowed down. Also, a decrease in core peripheral power at the end of the cycle reduced the effectiveness of hydrogen water chemistry (HWC) applied to reduce radiolytic oxygen and hydrogen peroxide and the subsequent electrochemical corrosion potential for mitigation of stress corrosion cracking since the downcomer dose rate became weaker with operation. These caused an increase in the sum of the oxygen and hydrogen peroxide concentrations at the same hydrogen injection rates and the effectiveness of HWC decreased. The effectiveness of noble metal chemical addition was not affected by changes in operating conditions at a 0.5 mg · kg–1 hydrogen injection rate.

PPCHEM® 2020, 22(1), 10–17

For Members only

Water Chemistry Management for the Primary Circuit of the First EPR Unit during Hot Functional Testing

Zhu Wang, Zhi-Wei Ge, and Zi-Tao Liu

The paper describes in detail the water chemistry control during the hot functional testing (HFT) of the first European pressurized reactor (EPR) unit worldwide, and focuses on the water chemistry control during passivation treatment of the component surfaces in the primary circuit with hydrogen injection, higher pH300°C and impurity control. Two identical surveillance coupons made of Inconel 690 TT steam generator (SG) tube samples were placed in the reactor pressure vessel (RPV) to evaluate the final passivation results. Water chemistry data and metallographic analysis results show that an excellent protective film was formed on the surface of the tubes, which reduces the corrosion rate of materials and the release of corrosion products, thereby also reducing radiation source terms during commercial operation of the unit. In addition, a brief comparison of the passivation film and passivation process between two types of the 3rd generation pressurized water reactors (PWRs), especially the hydrogen injection and zinc injection technologies, was made. The benefit of the passivation process during HFT for the dose rate is preliminary, and the dose rate reduction effectiveness also depends on the applied water chemistry control methods during future power operation of the unit.

PPCHEM® 2020, 22(1), 20–29

For Members only

2019’s Scientific and Technical Contributions

PPCHEM® 2020, 22(1), 48–55

Posted on

Issue 06 (2019)

Practical Observations and Interpretation of Oxide Growth and Exfoliation in Steam

Barry Dooley and Ian Wright

Over the last 40 years oxide growth and exfoliation (OGE) in superheater and reheater tubing have been responsible for a number of power plant problems which seriously have affected reliability. In the same time period, the authors have collected a data base of scale morphologies that has been used to describe in detail the progression of oxide scale development to the point where failure can occur. The concomitant evolution of knowledge of the factors that determine the mode of scale growth and failure in steam has provided the foundation for defining the specific stages in that progression, understanding differences among ferritic and austenitic alloys, and for categorizing the influence of plant operating characteristics. In particular, while tube/steam temperature and the maximum temperature drop at plant shutdown are major variables, the specific cycle chemistry used for the plant feedwater has very little influence. Key stages in the progression of scale growth to the point of failure are identified as OGE indices that are specific for ferritic and austenitic steels. These indices are intended to be used proactively to determine the current condition of a superheater or reheater on the path to exfoliation and possible plant damage. Also, by analyzing samples of exfoliant or oxide deposits responsible for damage, the origin of the oxide, and thus a possible superheater or reheater problem, can be identified retroactively.

PPCHEM® 2019, 21(6), 374–395

For Members only

ABHUG 2019 Highlights and Press Release

The first annual meeting of ABHUG held on the 30th October to 1st November 2019 in Brisbane, Australia was chaired by Barry Dooley of Structural Integrity Associates. This first ABHUG conference followed 11 annual meetings of AHUG (Australasian HRSG Users Group) and included conventional fossil plant technology and issues closely related to those in HRSGs. ABHUG 2019 attracted 75 participants from Australia, Japan, New Zealand, Thailand, UK, and USA. About 50% of the participants were Users, which is the highest of the other HRSG forums worldwide.

PPCHEM® 2019, 21(6), 396–397

IAPWS TGD10-19 Chemistry Management in Generator Water Cooling during Operation and Shutdown

The International Association for the Properties of Water and Steam

This Technical Guidance Document applies to all generators with water-cooled windings. From the operating side, adherence to a suitable water chemistry regimen as well as proper layup practices help to avoid or mitigate flow restrictions. Other influencing factors are design and materials. It is emphasized that this is an IAPWS Technical Guidance Document and that, depending on local requirements, the normal or target values will need to be customized for each case, depending on the actual conditions of operation and maintenance.

PPCHEM® 2019, 21(6), 400–439